Delta-electronics Programmable Logic Controller DVP-PLC Manuel d'utilisateur Page 93

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 586
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 92
2 Functions of Devices in DVP-PLC
DVP-PLC Application Manual
2-65
Special D Function
ES
EX
SS
SA
SX
SC
EH
EH2
SV
Off
Ø
On
STOP
Ø
RUN
RUN
Ø
STOP
Attribute Latched Default
D1444* Data length to be read on Salve ID#11
- - - R/W YES
16
D1445* Data length to be read on Salve ID#12
- - - R/W YES
16
D1446* Data length to be read on Salve ID#13
- - - R/W YES
16
D1447* Data length to be read on Salve ID#14
- - - R/W YES
16
D1448* Data length to be read on Salve ID#15
- - - R/W YES
16
D1449* Data length to be read on Salve ID#16
- - - R/W YES
16
D1450* Data length to be written on Slave ID#1
- - - R/W YES
16
D1451* Data length to be written on Slave ID#2
- - - R/W YES
16
D1452* Data length to be written on Slave ID#3
- - - R/W YES
16
D1453* Data length to be written on Slave ID#4
- - - R/W YES
16
D1454* Data length to be written on Slave ID#5
- - - R/W YES
16
D1455* Data length to be written on Slave ID#6
- - - R/W YES
16
D1456* Data length to be written on Slave ID#7
- - - R/W YES
16
D1457* Data length to be written on Slave ID#8
- - - R/W YES
16
D1458* Data length to be written on Slave ID#9
- - - R/W YES
16
D1459* Data length to be written on Slave ID#10
- - - R/W YES
16
D1460* Data length to be written on Slave ID#11
- - - R/W YES
16
D1461* Data length to be written on Slave ID#12
- - - R/W YES
16
D1462* Data length to be written on Slave ID#13
- - - R/W YES
16
D1463* Data length to be written on Slave ID#14
- - - R/W YES
16
D1464* Data length to be written on Slave ID#15
- - - R/W YES
16
D1465* Data length to be written on Slave ID#16
- - - R/W YES
16
D1466
Number of pulses required per revolution of motor at
CH0 (low word)
- - - R YES 2,000
D1467
Number of pulses required per revolution of motor at
CH0 (high word)
- - - R YES 0
D1468
Number of pulses required per revolution of motor at
CH1 (low word)
- - - R YES 2,000
D1469
Number of pulses required per revolution of motor at
CH1 (high word)
- - - R YES 0
D1470
Distance created for 1 revolution of motor at CH0
(low word)
- - - R YES 1,000
D1471
Distance created for 1 revolution of motor at CH0
(high word)
- - - R YES 0
D1472
Distance created for 1 revolution of motor at CH1
(low word)
- - - R YES 1,000