Train ing Kit O peratio n Manua l
4-1 0
An equivalent CANopen network is shown below.
The HMI displays the devices which are involved in data exchange.
HMI
Reading the temperature sent
by channels 1 in DVP04PT-S
D6032
Setting the frequency of
pulses sent by DVP28SV2
D6282
Setting the number of pulses
sent by DVP28SV2
D6284
High-speed count
D6033
Pulse output flag
M0
Count clearing flag
M1
2. The steps of setting the HMI are as follows.
Step 1: Set the frequency of pulses sent by DVP28SV2, and the number of pulses sent by
DVP28SV2
Step 2: Press the Pulse output button so that the state of the button is RUN.
Step 3: Press the Remove count value button so that the state of the button is ON. The state of
the Pulse output button becomes STOP. If users want to resume the output of pulses,
they have to set the Remove count value button to OFF, otherwise the Pulse output
button can not be set to RUN.
Note: When pulses are sent, users can set the frequency of pulses sent by DVP28SV2, but they
can not change the number of pulses sent by DVP28SV2.