Delta-electronics AC Servo Drive ASDA-B Manuel d'utilisateur Page 172

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 321
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 171
Chapter 7 Servo Parameters|ASDA-B Series
Revision February 2008, Doc. Name: 2006PDD23000009 7-19
7.3 Detailed Parameter Listings
Group 0: P0-xx Monitor Parameters
P0 - 00
VER Firmware Version Communication Addr.: 0000H
Default: Factory setting Related Section: N/A
Applicable Control Mode: P/S/T
Unit: N/A
Range: N/A
P0 - 01
ALE Drive Fault Code Communication Addr.: 0001H
Default: Factory setting Related Section:
Applicable Control Mode: P/S/T Chapter 10
Unit: N/A
Range: 1 ~ 20
Settings:
: Overcurrent (Note 1)
: Overvoltage (Note 2)
: Undervoltage (Note 2)
: Z Pulse shift (Note 3)
: Regeneration error (Note 1)
: Overload (Note 1)
: Overspeed (Note 1)
: Abnormal pulse control command (Note 1)
: Excessive deviation (Note 1)
: Serial communication error (Note 2)
: Encoder error (Position detector fault) (Note 3)
: Adjustment error (Note 1)
: Emergency stop (Note 2)
: Reverse (CWL) limit error (Note 2)
: Forward (CCWL) limit error (Note 2)
: IGBT temperature error (Note 2)
: Memory error (Note 4)
: Serial communication time out (Note 2)
: Motor type error (Note 2)
: Input power phase loss (Note 2)
Vue de la page 171