Chapter 7 Servo Parameters|ASDA-B Series
7-4 Revision February 2008, Doc. Name: 2006PDD23000009
Basic Parameters
Control
Mode
Parameter Name Function Default Unit
P S T
P1-44
GR1
Electronic Gear Ratio (1st Numerator)
(N1)
1 pulse
{
P1-45
GR2 Electronic Gear Ratio (Denominator) 1 pulse
{
P1-46
GR3 Encoder Output Pulse Number 2500 pulse
{ { {
P1-47
~ P1-51
Reserved
P1-52 RES1 Regenerative Resistor Value 40 Ohm
{ { {
P1-53 RES2 Regenerative Resistor Capacity 60 Watt
{ { {
P1-54 PER Positioning Completed Width 100 pulse
{
P1-55 MSPD Maximum Speed Limit rated speed rpm
{ { {
Explanation of symbols (marked after parameter)
() Read-only register.
() Parameter cannot be set when Servo On (when the servo drive is enabled).
() Parameter is effective only after the servo drive is restarted (after switching power off and on).
() Parameter setting values are not retained when power is off.