5
VFD-S Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-11
1 - 18
Jog Lassítási ideje
Factory Setting: d0.0
Settings d0.0 to d600
When Pr.1-18 is set to d0.0 Jog decelerating time determined by the setting of
Pr.1-13 0.1 to 600 sec, Jog decelerating time can be set independently, separates
from Pr.1-13
! When Pr.1-18 is set to 0.0, Pr.1-13 determines both Jog acceleration and deceleration
time. When Pr.1-18 is set between 0.1 to 600 seconds, which will determine Jog
Decelerating Time and Pr.1-13 will only determine Jog Accelerating Time.