Delta Electronics GBIC Interface Converters GBIC-1250B5QR Guide de l'utilisateur Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 38
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
Fabric Watch User’s Guide 2-3
Using Fabric Watch
2
A profile may contain the following information:
Threshold values:
- Unit string
- Time base
- Lower boundary
- Upper boundary
- Buffer size
Alarm values
- Change
- Exceed
- Below
- Above
- In-between
- Behavior type
Classes
Fabric and switch elements are organized into classes (also known as Agents), which are groupings
of closely related elements. The major classes are:
Fabric Monitors key fabric resources, such as fabric reconfiguration,
zoning changes, new fabric logins
Environmental Monitors switch environment functions, such as temperature,
power supply, fan status
Port Monitors port error and performance counters
E_Port Monitors E_Port error and performance counters
F/FL_Port (Optical) Monitors optical FL/F_Port error and performance counters
F/FL_Port (Copper) Monitors copper FL/F_Port error and performance counters
GBIC/SFP Monitors operational values for FINISAR smart GBICs and SFP
units
ALPA Monitors ALPA devices of Loop ports (currently CRC error of
ALPA device only).
Note: The ALPA class is only available if the optional
Performance Monitoring license has been purchased and
turned on.
End-to-End
1 - Monitors transmitting performance predefined by the
SID-DID pair. Configurable with either telnet commands or
Web Tools at run time.
2 - Monitors receiving performance predefined by the SID-DID
pair. Configurable with either telnet commands or Web Tools
at run time.
Vue de la page 14