Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
Revision January, 2008, Doc. Name: 2007PDD23000007 1-109
Moeller PLC Back to Table
A. HMI factory settings
Baud rate: 9600, 8, NONE, 1(RS-232).
Controller Station number: 2.
Control area/status area: MW0/MW10.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type Format
Word No. Bit No.
Data Length
Marker MW MWn n: 0-32766 N/A Byte
Diagnostic Status DSW DSWn n: 0-0 N/A Byte
Process Status PSW PSWn n: 0-0 N/A Byte
Diagnostic Counter DC DCn n: 0-15 N/A Word
Contacts
Read/Write Range
Contact type Format
Word No. Bit No.
Marker M Mn.b n: 0-32766 b: 0-7
Diagnostic Status DS DSn.b n: 0-1 b: 0-7
Process Status PS PSn.b n: 0-1 b: 0-7
C. Connections (Connector Pinouts)
RS-232
DOP
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
RXD (2)
5
TXD (3)
GND (5)
2
3
Top View