Delta-electronics DeviceNet Slave Communication Module DVPDT02-H2 Manuel d'utilisateur Page 25

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 24
DeviceNet Slave Communication Module DVPDT02-H2
DVP-PLC Application Manual
23
Attribute ID Access rule Name Data type
7 Get BaudRateSwitchChanged BOOL
8 Get MACIDSwitchValue USINT
9 Get BaudRateSwitchValue USINT
Common services
Implemented for
Service code
Class Instance
Service name
0x0E Yes Yes Get_Attribute_Single
0x10 No Yes Set_Attribute_Single
0x4B No Yes Allocate_Master/Slave_Connection_Set
0x4C No Yes Release_Master/Slave_Connection_Set
Class 0x05 – Connection object
Class attribute
Attribute ID Access rule Name Data type
1 Get Revision UINT
Instance 1: Explicit message connection
Attribute ID Access rule Name Data type
1 Get State USINT
2 Get InstanceType USINT
3 Get TransportClassTrigger USINT
4 Get ProducedConnectionId UINT
5 Get ConsumedConnectionId UINT
6 Get InitialCommCharacterisitcs BYTE
7 Get ProducedConnectionSize UINT
8 Get ConsumedConnectionSize UINT
9 Get/Set ExpectedPackedRate UINT
12 Get/Set WatcdogTimeoutAction USINT
13 Get
Produced Connection Path
Length
USINT
14 Get Produced Connection Path EPATH
15 Get
Consumed Connection Patch
Length
USINT
16 Get Consumed Connection Path EPATH
Instance 2: Polled I/O connection
Attribute ID Acccess rule Name Data type
1 Get State USINT
2 Get InstanceType USINT
3 Get TransportClassTrigger USINT
4 Get ProducedConnectionId UINT
5 Get ConsumedConnectionId UINT
6 Get InitialCommCharacteristics BYTE
7 Get ProducedConnectionSize UINT
Vue de la page 24
1 2 ... 20 21 22 23 24 25 26 27 28

Commentaires sur ces manuels

Pas de commentaire