Delta-electronics High-Speed PCI 12-Axis Motion Control Card PCI-DMC Manuel d'utilisateur Page 33

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 528
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 32
Chapter 3 Operating Principles | PCI-DMC-A01 / PCI-DMC-B01
Revised March, 2012 3-11
2) Enter the values of the arguments for motion control
Figure 3.18
NodeID item: API function's argument variable “NodeID”.
Timer Checkbox: Check to display the motion status. Uncheck to disable display.
Vel. item: Number of pulses per second. API function's argument variable
“MaxVel”.
Acc. item: Time required to reach maximum velocity. API function's argument
variable “acc”.
3) Set homing parameter (Homing mode and offset)
Figure 3.19
Mode item: Homing modes 1 to 35. API function's argument variable
“home_mode”.
Offset item: Homing offsetAPI function's argument variable “home_offset”.
4) Set Servo Motor Power ON/OFF(servo on/servo off)
Figure 3.20
Click on the “SVON” button to execute the following procedure:
rt = _DMC_01_ipo_set_svon(gDMCCardNo, NodeID, SlotID , ON_OFF);
// ON_OFF: 0 – Servo Power OFF; 1 – Servo Power ON
Vue de la page 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 527 528

Commentaires sur ces manuels

Pas de commentaire