Delta-electronics High-Speed PCI 12-Axis Motion Control Card PCI-DMC Manuel d'utilisateur Page 203

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 528
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 202
Chapter 9 Point to Point Motion Control Packet Protocol API | PCI-DMC-A01 / PCI-DMC-B01
Revised March, 2012 9-3
9.2 _DMC_01_start_sdo_driver_r_move
FORMAT
I16 PASCAL _DMC_01_start_sdo_driver_r_move (U16 CardNo, U16 NodeID, U16 SlotID,
I32 Distance)
Purpose
Starts relative motion displacement.
Parameters
Name Data Type Unit Description
CardNo U16 Number Unit CardNo is between 0~15
NodeID U16 Number Unit Node ID
SlotID U16 Number Unit Slot ID
Distance I32
Number of
pulses
Relative motion distance
Example
U16 CardNo=0;
U16 NodeID =1;
U16 SlotID = 0; //If Slot ID is set to 0, then the Slave is a servo drive
I32 Distance =10000000;
I16 status= _DMC_01_start_sdo_driver_r_move (CardNo, NodeID, SlotID, Distance);
Vue de la page 202
1 2 ... 198 199 200 201 202 203 204 205 206 207 208 ... 527 528

Commentaires sur ces manuels

Pas de commentaire