Evaluation Procedure
(DEP-001 A)
The Delphi DNM and DNL Series of
SIP type POL converters
The DNM and DNL, 2.4~5.5V or 10~14V input,
programmable output, non-isolated point of load
DC/DC converters, are the latest offering from
one of the world’s largest power supply
manufacturers Delta Electronics, Inc. The
DNM and DNL product family also has a flexible,
programmable tracking feature, which provides a
variety of startup voltages as well as sequencing
and tracking between power modules. With
creative design technology and optimization o
f
component placement, these converters possess
outstanding electrical and thermal performance,
as well as extremely high reliability under highl
y
stressful operating conditions. All models
possess a myriad of standard protection
features.
This document guides the user through the
evaluation procedures to qualify a POL module.
The data shown in this Evaluation Procedure is
for the SIP Package Type POL evaluation board.
Please refer to the data sheet for detailed
performance and technical information for the
specific POL units.
Evaluation Procedure
EP_DNML_SIP_08062004
DNM, DNL SIP Series
1.0 Purpose
This document guides the user in performing
electronic measurements on a DNM and DNL
POL (point of load) DC/DC converter by using
the Delta Evaluation Board.
2.0 Relevant Documentation
The documentation and background information
listed below is relevant to this evaluation
procedure:
2.1 Appropriate date sheet for the DNM or DNL
Series units.
2.2 Power Module Evaluation Board Schematic.
2.3 Power Module Evaluation Board Layout.
2.4 General Test and Safety Procedures.
Delta Electronics, Inc.
1
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - (DEP-001 A)

Evaluation Procedure (DEP-001 A) The Delphi DNM and DNL Series of SIP type POL converters The DNM and DNL, 2.4~5.5V or 10~14V input,programmable out

Page 2 - 3.0 Equipment Required

For DNM12xx and DNL12xx series ()7525.00667.07.0−×−= VoutVtrim V For example, to program the output voltage of a DNL12 module to 3.3 Vdc, Vtrim is c

Page 3

11 8.2.6 Voltage Tracking The DNM/DNL family was designed for applications that have output voltage tracking requirements during power-up and power

Page 4 - 7.0 Test Set-Up

12 Figure 4: Sequential Power up Figure 5: Sequential Power down Ratio-Metric Implementation Ratio–metric is implemented by the selection of

Page 5 - SW3 Function table

For Ratio-Metric applications that need the PS1 and PS2 outputs arrive regulation set point at same time, use equation 1 to calculate R1, set △ V=V

Page 6 - 8.0 Tests and Evaluation

14 For example, the PS1 Voset,PS1=5V, the PS2 Voset,PS2=3.3V, R1 is calculated as follows: KKR 303.1020*32.1]32.1)3.13.3[(1 =−−= Ω Figure 9.

Page 7

15 For type C (DNXXX0A0XXXX C), the simultaneous tracking can be accomplished by putting R1 equal to 30.1K Ω through VoPS1 to the TRACK pin of PS2. F

Page 8

16 Notes on the use of Track function: 1. For proper voltage tracking, first, The ENABLE On/Off pin of the PS2 module is leftunconnected (or tied t

Page 9

Test 1) Turn on the fan. 2) Adjust the input voltage to the desired operating point. 3) Set the electronic or resistive load at 50% of maximum lo

Page 10

4. Connect a scope probe from channel 1 between the on/off control pin and referenceground (SGND) on the Evaluation Board. 5. Set channel 2 on the

Page 11

Appendix A- Evaluation Board Schematic 19

Page 12

2 3.0 Equipment Required 3.1 A DC Power Supply 0 - 20 V @ 0 - 20A (Agilent 6574A 0 -60V/0 - 35A or equivalent). 3.2 An oscilloscope (Tektronix T

Page 13

Appendix B - Evaluation Board Layout (Top View) Appendix C - Evaluation Board Layout (Bottom View) CONTACT DATA: www.de

Page 14

3 4.1 Connect one lead from the “+” lead of the DC source (See Item 3.1) to the “20A” terminal of the first multi-meter DVM1 (See Item 3.3). Then conn

Page 15

4 6.0 Tests Performed The following tests are performed at room temperature (+25 ℃). 6.1 Input Characteristics  Input Voltage Range.  Under-Vol

Page 16

5 5) SW2 is used to enable or disable the converter. For positive logic module, When SW2 is pose for the ON position, the converter is ON, and SW2

Page 17

6 8.0 Tests and Evaluation 8.1 Input Characteristics 8.1.1 Input Voltage Range and Under-Voltage Lockout The DNM04xx and DNL04xx Series of DC/DC

Page 18 - 8.4.1 Efficiency

7 8.2 Output Characteristics 8.2.1 Line Regulation Line Regulation Deviation is defined as the change in output voltage caused by varying the input

Page 19

8 8.2.4 Output Voltage Set-point Programming (1) Output Voltage Set-Point Adjustment by external resistor Output Voltage Set-point Programming can

Page 20 - Warranty

Table 2. Vo,set Rset (kΩ) R33 Recommend Value, R//R 0.7525 Open Open 1.2 22.464 23.7k//432k 1.5 13.047 14.0k//191k 1.8 9.024 9.53k//169k 2.