Mode Tiger
Dimmable Power Unit
MODE LIGHTING (UK) LIMITED
The Maltings, 63 High Street, Ware, Hertfordshire, SG12 9AD, England.
Tel: +44 (0) 1920 462121 e-mail: [email protected] Fax: +44 (0) 1920 466881
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - Dimmable Power Unit

Mode TigerDimmable Power UnitMODE LIGHTING (UK) LIMITEDThe Maltings, 63 High Street, Ware, Hertfordshire, SG12 9AD, England.Tel: +44 (0) 1920 462121 e

Page 2

This unit is to be wired by a suitably qualified electrician in accordancewith National Wiring Regulations and other applicable Re

Page 3 - TP-10-06 and TP-06-09

OUTPUT WIRING TP-06-09 (9 CHANNEL)CHANNEL OUTPUT TERMINALS9 Live output terminals (6.6 amp max.).9 Neutral output terminals (6.6 amp

Page 4

10EXTERNAL CONNECTORS (top plate)CONTROL WIRING (LOW VOLTAGE)RS-232 9 way D connector - for future use.5 Pin XLR chassis socket for DMX

Page 5

11CONTROL MODULE SETTINGSDisplay showing start address.For future use.Push button increment 100's for start address.Push button in

Page 6 - MECHANICAL FIXING

12POWER MODULE FUNCTIONSTWIN MODULE used in 6 channel model TP-10-06Heatsink and mounting bracketRFI noise suppression chokesChannel

Page 7

13INDICATOR IDENTIFICATIONThe three neons shown indicate when the phase input is live.Phase 1Phase 2Phase 3The three green neons show

Page 8

TECHNICAL SPECIFICATION TP-10-06 (6 CHANNEL)POWER Voltage 230V AC nominal. (207V - 253V), 50Hz.SUPPLY (110V 60Hz AC nominal available

Page 9 - MAINS SUPPLY WIRING

TECHNICAL SPECIFICATION TP-06-09 (9 CHANNEL)POWER Voltage 230V AC nominal. (207V - 253V), 50Hz.SUPPLY (110V 60Hz AC nominal available

Page 10

16 Periodically inspect the wiring for damage.Ensure the ventilation holes have not become covered or blocked with dust.Check overall

Page 13 - CONTROL MODULE SETTINGS

Mode Lighting (UK) Limited was established in 1970 as a manufacturer ofelectronic componets for the lighting industry. Mode has an enviablereputation

Page 14 - POWER MODULE FUNCTIONS

Page1.2.3.4. 5.6.7.8.9.10.11.12.13.14.15.16.17.ContentsIntroductionInstallation procedureMechanical fixingIdentification of terminals TP-10-06

Page 15 - INDICATOR IDENTIFICATION

INTRODUCTION2FOUNDATION: Mode was established in 1970 as an Original Equipment Manufacturer in Hertfordshire, England. Mode designs and

Page 16

3INSTALLATION PROCEDURE1. Remove all packaging.2. Read instructions and retain for future reference.3. Fit unit to wall and observe spa

Page 17

MECHANICAL FIXING Mark positions, drill holes and fit screws to wall, see diagram below. Dimensions in millimetres.Hang unit on screw

Page 18 - Mode Lighting UK Limited

IDENTIFICATION OF TERMINALS TP-10-06 (6 CHANNEL)5PHASE INPUT NEONSDMX / SCENARIOINPUT TERMINALSANALOGUE INPUT /OUTPUT TERMINALSSTART ADD

Page 19

IDENTIFICATION OF TERMINALS TP-06-09 (9 CHANNEL)PHASE INPUT NEONSDMX / SCENARIOINPUT TERMINALSANALOGUE INPUT /OUTPUT TERMINALSSTART ADDR

Page 20

MAINS SUPPLY WIRINGCONNECTIONConnect three live input feeds using wire of between the values stated above and in accordance with the