Delta-electronics H48SL Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Outils Delta-electronics H48SL. Delta Electronics H48SL User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 14
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Delphi Series H48SL, 200W Half Brick Family
DC/DC Power Modules: 48V in, 1.5V/60A out
The Delphi Series H48SL Half Brick, 48V input, single output, isolated
DC/DC converters are the latest offering from a world leader in powe
r
systems technology and manufacturing Delta Electronics, Inc. This
product family provides up to 200 watts of power (3.3V and above) o
r
60A of output current in an industry standard footprint. With creative
design technology and optimization of component placement, these
converters possess outstanding electrical and thermal performance, as
well as extremely high reliability under highly stressful operating
conditions.
A
ll models are fully protected from abnormal input/outpu
t
voltage, current, and temperature conditions. The Delphi Series
converters meet all safety requirements with basic insulation.
OPTIONS
Positive Remote On/Off logic
Negative trim
Short pin lengths
APPLICATIONS
Telecom/Datacom
Wireless Networks
Optical Network Equipment
Server and Data Storage
Industrial/Test Equipment
FEATURES
High Efficiency: 84% @ 1.5V/60A
Size: 57.9 x 61.0 x 12.7mm
(2.28” x 2.40” x 0.50”)
Standard footprint
Industry standard pin out
Fixed frequency operation
Metal baseplate
Input UVLO, Output OCP, OVP, OTP
Basic insulation
No minimum load required
2:1 Input voltage range
ISO 9001, TL 9000, ISO 14001, QS9000,
OHSAS18001 certified manufacturing
facility
UL/cUL 60950 (US & Canada)
Recognized, and TUV (EN60950)
Certified
CE mark meets 73/23/EEC and
93/68/EEC directives
DATASHEET
DS_H48SL1R560_10302006
Vue de la page 0
1 2 3 4 5 6 ... 13 14

Résumé du contenu

Page 1 - FEATURES

Delphi Series H48SL, 200W Half Brick Family DC/DC Power Modules: 48V in, 1.5V/60A out The Delphi Series H48SL Half Brick, 48V input, single output,

Page 2 - TECHNICAL SPECIFICATIONS

FEATURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-current protection circuit, which will endure current limi

Page 3 - DS_H48SL1R560_10302006

FEATURES DESCRIPTIONS (CON.) Output Voltage Adjustment (TRIM) To increase or decrease the output voltage set point, connect an external resistor bet

Page 4

THERMAL CONSIDERATIONS Thermal management is an important part of the system design. To ensure proper, reliable operation, sufficient cooling of the

Page 5

MECHANICAL DRAWING Pin No. Name Function1 2 3 4 5 6 7 8 9 -Vin Case ON/OFF +Vin +Vout +SENSE TRIM -SENSE -Vout Negative input voltage Case ground

Page 6

DS_H48SL1R560_10302006 14 PART NUMBERING SYSTEM H 48 S L 1R5 60 N R F A Form Factor Input Voltage Number of Outputs Product Series Output Volt

Page 7

TECHNICAL SPECIFICATIONS (TA=25°C, airflow rate=300 LFM, Vin=48Vdc, nominal Vout unless otherwise noted) PARAMETER NOTES and CONDITIONS H48SL1R560 (S

Page 8 - Convection

ELECTRICAL CHARACTERISTICS CURVES 65707580859010 20 30 40 50 60OUTPUT CURRENT (A)EFFICIENCY (%)36Vin 48Vin 75Vin0.04.08.012.016.020.010 20 30 40 50 60

Page 9 - DESIGN CONSIDERATIONS

ELECTRICAL CHARACTERISTICS CURVES For Negative Remote On/Off Logic Figure 4: Turn-on transient at full rated load current (resistive load) (2 ms/div)

Page 10 - FEATURES DESCRIPTIONS

ELECTRICAL CHARACTERISTICS CURVES Figure 8: Output voltage response to step-change in load current (75%-50%-75% of Io, max; di/dt = 0.1A/µs). Load cap

Page 11 - FEATURES DESCRIPTIONS (CON.)

ELECTRICAL CHARACTERISTICS CURVES Figure 11: Input Terminal Ripple Current, ic, at full rated output current and nominal input voltage with 12µH sourc

Page 12 - THERMAL CONSIDERATIONS

ELECTRICAL CHARACTERISTICS CURVES 0.00.20.40.60.81.01.21.41.60 102030405060708090100LOAD CURRENT (A)OUTPUT VOLTAGE (V)48VinFigure 14: Output voltage r

Page 13 - MECHANICAL DRAWING

THERMAL CURVES: NO HEATSINK, EITHER ORIENTATION Figure 16: Case temperature measurement location. Pin locations are for reference only. Figure 17: O

Page 14 - MODEL LIST

DESIGN CONSIDERATIONS Input Source Impedance The impedance of the input source connecting to the DC/DC power modules will interact with the modules